Deflating Expectations |
| Written by Kent Lupino |
| Category: BP Measurement |
| Monday, 09 January 2012 |
|
One of the more recent ones is aptly titled, “Blood Pressure Monitoring Technique Impacts Hypertension Treatment”. Authored by Ray et al and published in the Journal of General Internal Medicine, this study compared the way that BP’s are normally taken during triage check-in on a population of 40 patients at the New Mexico Hospital Adult Internal Medicine Clinic. A study investigator observed the technique used by the clinician, and then took the patient’s BP using the AHA recommendations for blood pressure measurement published in 2005. Variances in the triage technique from the AHA recommendations were documented, as well as differences in blood pressure readings. The study found, somewhat unsurpringly, that individual BP measurements varied greatly between the two methods, and that multiple technical errors were seen using the uncontrolled triage technique. And while the authors reported a plethora of technical non-adherence to ten of the AHA’s recommendations—from not measuring on both arms, to placing the cuff over clothing, to applying the wrong-sized cuff, and more—I was shocked to find that the study authors failed to include one of the most important recommendations: cuff deflation rate. The AHA recommendations state that, “The cuff should initially be inflated to at least 30 mm Hg above the point at which the radial pulse disappears. The rate of deflation has a significant effect on blood pressure determination. Deflation rates >2 mm per second can lead to a significant underestimation of systolic and overestimation of diastolic blood pressure…It is recommended that a deflation rate of 2 to 3 mmHg per second (or per pulse when the heart rate is very slow) be used.”1 Okay, now it’s time for an anecdote. On a recent visit to the doctor’s office, a nurse escorted me to the exam room and proceeded to take my blood pressure as usual. She deflated the cuff so amazingly fast, the sphyg needle was practically a blur. I had been taking my BP’s at home and at work for a while so I had a good idea of what my BP should have been, but after her speed reading she calmly reported systolic and diastolic readings that I knew were each off by double-digits. To be fair, it’s not just that particular nurse. While she may have a particularly aggressive deflate style, virtually every clinician I’ve ever observed—doctors included—deflate faster than 2 to 3 mmHg per second. So I was somewhat shocked to discover that Ray et al did not include deflation rate in their study, or even say whether or not the study investigators adhered to the 2–3mmHg rule! I applaud their efforts, and firmly believe that more research like it should be done. But next time, please include deflation rate. 1 Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals. Part 1: blood pressure measurement in humans. A statement for professionals from the subcommittee of professional and public education of the American Heart Association council on high blood pressure research. Circulation. 2005; 111:697-716. Keywords: |
Recent Articles by Kent Lupino:
Follow us on Twitter
Download Free eBooks!
Top 7 Reasons to Use Disposable BP Cuffs to Reduce the Transmission of HAIs
Also see: 10 Steps to Accurate Manual Blood Pressure Measurement
Recent Popular Posts
- 10 Things To Look For When Purchasing Disposable Cuffs
- Top 7 Reasons You Should Be Using Automated Blood Pressure for Cardiac Stress Testing
- 5 Myths About Vital Signs Automation and EHR's
- BP Differences Between Arms Could be an Early Indicator of Serious Health Risks Ahead
- You’re Doing It Wrong: New Study on BP Measurement
Posts by Date
| < | May 2012 | > | ||||
| Sun | Mon | Tue | Wed | Thu | Fri | Sat |
| 1 | 2 | 3 | 4 | 5 | ||
| 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| 13 | 14 | 15 | 16 | 17 | 18 | 19 |
| 20 | 21 | 22 | 23 | 24 | 25 | 26 |
| 27 | 28 | 29 | 30 | 31 | ||
Browse by Keyword
- abpm (17)
- accurate blood pressure measurement (6)
- ambulatory blood pressure monitoring (17)
- automated blood pressure measurement (5)
- automated bp (4)
- automated bp measurement (6)
- blood pressure (16)
- blood pressure cuffs (11)
- blood pressure measurement (21)
- blood pressure technology (8)
- bp cuffs (11)
- bp measurement (26)
- high blood pressure (21)
- hypertension (28)
- hypertension in children (4)
- infection control (3)
- oem (6)
- oem nibp (10)
- pediatric abpm (4)
- pediatric bp (4)

ENG
中文
We’ve written quite a bit here on the SunTech blog about
@suntechmed
